| PRAMAC P 12000 |
 |
Item code: PF113TZA000

(purely indicative picture) |
Main features
| Rated maximum power (LTP) | : | 12,6 kW | | Rated prime power (PRP) | : | 9,7 kW | | Phases | : | 3 Y | | Voltage | : | 230, 400 V | | Frequency | : | 50 Hz | | Engine manufacturer | : | Hatz | | Fuel | : | Diesel | | Starting system | : | Electric |
P Series
The P Series are exceptionally quiet and high powered portable generators, for residential areas or working sites where special respect for noise levels is required.
|
| Single-phase maximum power (LTP) | 10,42 kVA | | Single-phase maximum power (LTP). | 9,38 kW | | Single-phase prime power (PRP) | 4,4 kVA | | Single-phase prime power (PRP). | 3,96 kW | | Single-phase continuous power (COP) | 4 kVA | | Single-phase continuous power (COP) | 3,6 kW | | Rated maximum power (LTP) | 15,79 kVA | | Rated maximum power (LTP) | 12,6 kW | | Rated prime power (PRP) | 12,1 kVA | | Rated prime power (PRP) | 9,7 kW | | Rated continuous power (COP) | 11 kVA | | Rated continuous power (COP) | 8,8 kW | | Rated current at COP | 15,9 A | | Phases | 3 Y | | Voltage | 230, 400 V | | Rated power factor | 0,8 PF | | Frequency | 50 Hz | | Battery charger voltage | n.a. | | Battery charger current | n.a. | | Panel location | Canopied | | Frame type | Canopied | | Compliancy certification | CE |
|
| Engine manufacturer | Hatz | | Model | 2 G 40 | | Stroke | 4 | | Fuel | Diesel | | Number of cylinders and disposition | 2, inline | | Displacement | 997 cm³ | | Air intake | Natural | | Starting system | Electric | | Nominal operating speed | 3000 rpm | | Speed governor | Mechanical | | Continuous power COP | 13,1 kW | | Prime power PRP | 14,4 kW | | Standby power LTP | 15,4 kW | | Lube oil capacity | 2,5 l | | Fuel consumption at 75% load | 2,25 l/h | | Electric circuit voltage | 12 V |
|
| Alternator specifications |
| Alternator manufacturer | Zanardi | | Model | AT 118 L12 | | Poles | 2 | | Revolution speed | 3000 rpm | | Voltage | 400 V | | Frequency | 50 Hz | | Efficiency at 75% load | 82 % | | Maximum admitted overload | 10% for 1 hour every 6 hours of running time S2 | | Voltage regulation system | Compound | | Protection grade | IP 23 |
|
| Skid mounting | Yes | | Fuel tank location | On canopy | | Fuel tank capacity | 17 l | | Automatic supplementary tank VV.FF. | No | | Running time at 75% COP | 7,55 h | | Measured acoustic power (LWA) at 4 mt | 96,5 dBA | | Noise level at 7 m | 71,5 dBA | | Guaranteed noise level (LWA) | 97 dBA | | Operating conditions | -30 ~ +45 °C |
|
| Length | 1270 mm | | Width | 830 mm | | Height | 920 mm | | Dry weight | 275 kg |
|
| Ammeter | No | | Frequency meter | No | | Hourmeter | Yes | | Isometer | Yes | | Voltmeter | Yes | | Voltage presence indicator | Yes | | Fuel level gauge | No | | Lube oil pressure gauge | No | | Lube oil pressure indicator | Yes | | High temperature indicator | No | | Water thermometer | No | | Electronic speed regulator (± 0,25%) | No | | Remote control (up to 40 m) | Optional | | Ecologizer | No | | Star-Delta switch | Yes | | Connector for AMF (Automatic Mains Failure) panel | No | | AMF (Automatic Mains Failure) panel | Optional | | SAS (automatic start system) | No | | Engine oil preheater | No | | Automatic engine shut down system | No | | Overspeed shutdown | No | | High temperature engine shut down | No | | Emergency stop | No | | Thermal protection | No | | Magnetothermic protection | Yes | | Minimum-maximum voltage relay | No | | 115-230 voltage switch | No | | ELCB (Earth Leakage Circuit Breaker) | Optional | | Lube oil guard | No | | Wheels and handles | Yes | | Lifting kit | Yes | | Job site trailer | No | | Road trailer | No |
|
| CEE 2P+T 230V 16A | 1 | | CEE 3P+N+T 400V 16A | 1 | | CEE 3P+T 230V 32A | 1 |
|
Technical specifications are subject to change without notice. Consult your local PRAMAC representative for more information.
|
|